รายละเอียดสินค้า : |
|
|
|
|
The DMHFP adopt the MultiPulseTM Technology, Digital Signal Processing |
Technology and Error Correction Technology, which are the state-of-the-art non-invasive |
flow measurement technology, with a measuring system of very high accuracy, versatility, |
low cost of installation and ownership. The meter can calculate automatically caloric |
content of water under carious temperatures, and can obtain instantaneous caloric value |
and totalized caloric value. |
|
The Non-invasive clamp-on series and the Insertion series are available. |
Users can select fixed types or Portable types. |
The pipe range should be 25mm-2540mm (For Insertion series, the allowed pipe range |
is 65mm-2540mm) |
|
|
|
|
คุณสมบัติทางด้านเทคนิค : |
|
|
|
|
▪ Non-invasive clamp-on series transducer and Insertion eries transducer are available. |
▪ Internally configured batch controller makes batch control convenient and accurate. |
▪ No moving parts, no pressure drop, no need of maintenance. |
▪ Easy and economical installation, hot-tapped installation. |
▪ Daily, monthly and yearly totalized flow: totalized flow for the last 64 days and months |
as well as for the last 5 years can be reviewed. |
▪ Optional SD card Data logger output, can memory total Heat Flow, Heat flow rate, etc. |
|
|
|
Transmitter |
Power Supply |
(Std) 10-28 VDC @ 2.5VA max.115/230VAC 50/60Hz |
|
|
±15%@ 5VAmax. or rechargeable battery. |
|
Velocity |
0 to ±40 ft/s (0 to ±12m/s), bi-directional |
|
Display |
4 line X 16 English letters LCD back lit, can display |
|
|
total flow, flow rate, velocity and meter running |
|
|
status etc. |
|
Units |
User Configured (English and Metric); |
|
Rate |
Rate and Velocity Display; |
|
Totalized |
(FWD, NET, REV or BATCH) gallons, ft³, barrels, lbs, |
|
|
litters, m³,kg |
|
Output |
4 to 20mA, Pulse, Relay, RS232C or RS485, |
|
|
options: up to 8 GB Data logger, Hart +(4 to 20mA), |
|
|
Modbus |
|
Accuracy |
±1.0% of reading at rates >0.5 m/s |
|
|
±2.0% of reading at rates <0.5 m/s |
|
Sensitivity |
Flow Rate: 0.001ft/s (0.0003m/s) |
|
Repeatability |
0.2% of reading |
|
Security |
Keypad lockout, access code enable |
Transducer |
Liquid Types |
Virtually most any liquid containing less than 2% |
|
Supported |
total suspended solids (TSS) or aeration |
|
Suited Liquid |
Std. Temp. Transducer : -40 Deg C to 121Deg C |
|
Temperature |
High Temp. Transducer : -40 Deg C to 250Deg C |
|
Cable Length |
Std: 20 feet (6m); Opt: Maximum: 990 feet (300m) |
|
Dimensions |
S: Size : 42*25*25; weight:<0.3kg |
|
and Weight |
M: Size : 60*43*43; weight:<0.6kg |
|
|
L: Size : 80*53*53; weight:<1.0kg |
|
Pipe Size |
L transducer: DN1000 - 4500 |
|
|
M transducer: DN40 -1000 |
|
|
S transducer: DN15 - 50 |
|
|
Insertion transducer: DN65 2500 |
|
|
Flanged transducer: DN65 2500 |
Temperature |
Temperature |
C1-Pt100 : (-40~150℃) Two-Wire System Temperature |
Sensor |
Input Type |
transmitter input |
|
|
C2-Pt1000 : (-40~150℃) Two-Wire System Temperature |
|
|
transmitter input |
|
|
|